SL Series 1.5 kW to 6 kW
Features
High Frequency IGBT-based Switch-Mode Design
The SL Series utilizes the latest IGBT devices to drive down size and increase performance. The high frequency design delivers fast transient response and low output ripple. This performance coupled with Magna-Power's rugged current-fed power processing, enables confidence in even the most demanding applications.
Fully Programmable Power
All SL Series functions and features of are available and programmable from a variety of control methods, including:
- Stepless front panel knobs
- 37-pin isolated analog-digital I/O
- Computer interface with software and drivers
Various programming interfaces are available, such as LXI TCP/IP Ethernet (+LXI), IEEE-488 GPIB (+GPIB), Edgeport USB, Accessory (+USB), RS485 Accessory (+RS485).
Model Ordering Guide
Models Chart
The following chart details the available standard SL Series models. The Current Maximum (Adc) column is separated by the available power levels. To determine the appropriate model, first select your output Voltage Maximum (Vdc) to find appropriate row. Next, select one desired Current Maximum from the row that contains your desired Voltage Maximum. Then, construct your model number according to the model ordering guide, above. Non-standard voltage and current configurations are available.
1.5 kW | 2.6 kW | 4 kW | 6 kW | |||
---|---|---|---|---|---|---|
Voltage Maximum | Current Maximum | Ripple (mVrms) | Efficiency (%) | |||
5 | 250 | N/A | N/A | N/A | 50 | 86 |
10 | 150 | 250 | N/A | N/A | 40 | 86 |
16 | 93 | 162 | 250 | N/A | 35 | 86 |
20 | 75 | 130 | 200 | 250 | 40 | 86 |
25 | 60 | 104 | 160 | 240 | 40 | 86 |
32 | 46 | 81 | 125 | 186 | 40 | 86 |
40 | 37 | 65 | 100 | 150 | 40 | 87 |
50 | 30 | 52 | 80 | 120 | 50 | 87 |
60 | 25 | 43 | 66 | 100 | 60 | 87 |
80 | 18 | 32 | 50 | 75 | 60 | 87 |
100 | 15 | 26 | 40 | 60 | 60 | 87 |
125 | 12 | 20 | 32 | 48 | 100 | 87 |
160 | 9 | 16 | 25 | 36 | 120 | 87 |
200 | 7.5 | 13 | 20 | 30 | 125 | 87 |
250 | 6 | 10.4 | 16 | 24 | 130 | 88 |
300 | 5 | 8.6 | 13.2 | 20 | 160 | 88 |
375 | 4 | 6.9 | 10.4 | 16 | 170 | 88 |
400 | 3.7 | 6.5 | 10 | 15 | 180 | 88 |
500 | 3 | 5.2 | 8 | 12 | 220 | 88 |
600 | 2.5 | 4.3 | 6.4 | 10 | 250 | 88 |
800 | 1.8 | 3.2 | 5.0 | 7.5 | 300 | 88 |
1000 | 1.5 | 2.6 | 4.0 | 6.0 | 350 | 88 |
Input Current Per Phase (Aac) | ||||||
UI (85 - 265 Vac, 1Φ) | 21 - 7 | N/A | N/A | N/A | ||
208/240 Vac, 3Φ | 6 | 11 | 16 | 24 | ||
380/415 Vac, 3Φ | 5 | 8 | 11 | 16 | ||
440/480 Vac, 3Φ | 4 | 6 | 9 | 14 |
Specifications
Input Specifications | |
---|---|
Nominal Voltage 1 phase, 2 wire + ground (Available on 1.5 kW Models Only) |
85 - 265 Vac, 1Φ (UI—Universal input) |
Nominal Voltage 3 phase, 3 wire + ground (Available on All Models) |
208 VAC (operating range 187 - 229 VAC) 240 VAC (operating range 216 - 264 VAC) 380 VAC (operating range 342 - 440 VAC) 415 VAC (operating range 373 - 456 VAC) 440 VAC (operating range 396 - 484 VAC) 480 VAC (operating range 432 - 528 VAC) |
Frequency | 50 Hz through 400 Hz |
Power Factor |
0.99 at maximum power for 1Φ units > 0.82 at maximum power for 3Φ units |
Output Specifications | |
---|---|
Ripple | See Model Charts |
Line Regulation |
Voltage Mode: ± 0.004% of full scale Current Mode: ± 0.02% of full scale |
Load Regulation |
Voltage Mode: ± 0.01% of full scale Current Mode: ± 0.04% of full scale |
Load Transient Response | 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
Efficiency | ≥ 86% (See Model Charts) |
Stability | ± 0.10% for 8 hrs. after 30 min. warmup |
Isolation |
Maximum input voltage to ground: ±2500 Vac Maximum output voltage to ground: ±1000 Vdc User inputs and outputs: referenced to earth ground |
Maximum Slew Rate |
Standard Models: 100 ms for an output voltage change from 0 to 63%, 100 ms for an output current change from 0 to 63%. With High Slew Rate Option (+HS): 4 ms for an output voltage change from 0 to 63%, 8 ms for an output current change from 0 to 63%. |
Bandwidth |
Standard Models: 3 Hz with remote analog voltage programming, 2 Hz with remote analog current programming. With High Slew Rate Option (+HS): 60 Hz with remote analog voltage programming, 45 Hz with remote analog current programming. |
Physical Specifications | |||
---|---|---|---|
Power | Size (H" x W" x D") | Rack Units | Weight |
1.5 kW | 1.75" x 19" x 24" (4.44 x 48.3 x 61.0 cm) | 1U | 32 lbs (14.52 kg) |
2.6 kW | 1.75" x 19" x 24" (4.44 x 48.3 x 61.0 cm) | 1U | 34 lbs (15.42 kg) |
4 kW | 1.75" x 19" x 24" (4.44 x 48.3 x 61.0 cm) | 1U | 35 lbs (15.88 kg) |
6 kW | 1.75" x 19" x 24" (4.44 x 48.3 x 61.0 cm) | 1U | 35 lbs (15.88 kg) |
Control Specifications | |
---|---|
Voltage Programming Accuracy | ± 0.075% of full scale voltage |
OVT Programming Accuracy | ± 0.075% of full scale voltage |
Current Programming Accuracy | ± 0.075% of full scale current |
OCT Programming Accuracy | ± 0.075% of full scale current |
Voltage Readback Accuracy | ± 0.2% of full scale voltage |
Current Readback Accuracy | ± 0.2% of full scale current |
External Analog Programming and Monitoring Levels | 0 - 10 Vdc |
External Analog Output Impedances |
Voltage output monitoring: 100 Ω Current output monitoring: 100 Ω +10 Vdc reference: 1 Ω |
External Digital Programming and Monitoring Limits |
Input: 0 to 5 Vdc, 10 kΩ input impedance Output: 0 to 5 Vdc, 5 mA drive capacity |
Remote Sense Limits | 3% maximum voltage drop from output to load |