TS Series 5 kW to 45 kW

TS Series 5 kW to 45 kW

Share:


TS Series 5 kW to 45 kW

Features

High Frequency IGBT-based Switch-Mode Design

The TS Series utilizes the latest IGBT devices to drive down size and increase performance. The high frequency design delivers fast transient response and low output ripple. This performance coupled with Magna-Power's rugged current-fed power processing, enables confidence in even the most demanding applications.
 

Fully Programmable Power

All TS Series functions and features of are available and programmable from a variety of control methods, including:

  • Stepless front panel knobs
  • 37-pin isolated analog-digital I/O
  • Computer interface with software and drivers

Various programming interfaces are available, such as LXI TCP/IP Ethernet (+LXI), IEEE-488 GPIB (+GPIB), Edgeport USB, Accessory (+USB), RS485 Accessory (+RS485).
 

Model Ordering Guide

Models Chart

The following chart details the available standard TS Series models. The Current Maximum (Adc) column is separated by the available power levels. To determine the appropriate model, first select your output Voltage Maximum (Vdc) to find appropriate row. Next, select one desired Current Maximum from the row that contains your desired Voltage Maximum. Then, construct your model number according to the model ordering guide, above. Non-standard voltage and current configurations are available.
 

5 kW 10 kW 15 kW 20 kW 25 kW 30 kW 45 kW    
Voltage Maximum Current Maximum Ripple (mVrms) Eff. (%)
5 900 1800* 2700* N/A N/A N/A N/A 50 86
8 600 1200* N/A N/A N/A N/A N/A 40 86
10 500 900 1800* N/A 2700* N/A N/A 40 86
16 300 600 900 1200 1500 1800 2700 35 86
20 250 500 750 1000 1250 1500 2250 40 86
25 200 400 600 800 1000 1200 1800 40 86
32 150 300 450 600 750 900 1350 40 86
40 125 250 375 500 625 750 1125 40 87
50 100 200 300 400 500 600 900 50 87
60 83 166 249 342 415 498 747 60 87
80 62 124 186 248 310 372 558 60 87
100 50 100 150 200 250 300 450 60 87
125 40 80 120 160 200 240 360 100 87
160 31 62 93 124 155 186 279 120 87
200 25 50 75 100 125 150 225 125 87
250 20 40 60 80 100 120 180 130 88
300 16 32 48 64 80 96 144 160 88
375 13 26 39 52 65 78 117 170 88
400 12 24 36 48 60 72 108 180 88
500 10 20 30 40 50 60 90 220 88
600 8 16 24 32 40 48 72 250 88
800 6 12 18 24 30 36 54 300 88
1000 5 10 15 20 25 30 45 350 88
1250 4 8 12 16 20 24 36 375 88
1500 3.3 6.6 9.9 13.2 16.5 19.8 29.7 400 88
2000 2.5 5.0 7.5 10.0 12.5 15.0 22.5 450 88
3000 1.6 3.2 4.8 6.4 8.0 9.6 14.4 500 88
4000 1.2 2.4 3.6 4.8 6.0 7.2 10.8 550 88
  Input Current Per Phase (Aac)    
208/240 Vac, 1Φ 38 N/A N/A N/A N/A N/A N/A    
208/240 Vac, 3Φ 19 36 54 72 90 108 162    
380/415 Vac, 3Φ 10 21 30 40 50 60 90    
440/480 Vac, 3Φ 9 18 27 36 45 54 81  

Specifications

Input
Nominal Voltage
3 phase, 3 wire + ground
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
380 VAC (operating range 342 - 440 VAC)
415 VAC (operating range 373 - 456 VAC)
440 VAC (operating range 396 - 484 VAC)
480 VAC (operating range 432 - 528 VAC)
1 phase, 2 wire + ground
(5 kW models only)
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
Frequency 50 through 400 Hz (operating range 45 Hz to 440 Hz)
Power Factor Greater than 92% at maximum power for 3 phase models,
Greater than 70% at maximum power for 1 phase models.
Output Specifications
Ripple See Model Charts
Line Regulation Voltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale
Load Regulation Voltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale
Load Transient Response 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change
Efficiency ≥ 86% (See Model Charts)
Stability ± 0.10% for 8 hrs. after 30 min. warmup
Isolation User inputs and outputs: referenced to earth ground.
Maximum input voltage to ground: ±2500 Vac
Maximum output voltage to ground:
±1000 Vdc for models less than or equal to 1000 Vdc,
±(2000 Vdc + Vo/2) for models greater than 1000 Vdc or with High Isolation Output Option (+ISO) where Vo is the maximum output voltage of the power supply.
Maximum Slew Rate Standard Models:
100 ms for an output voltage change from 0 to 63%,
100 ms for an output current change from 0 to 63%.
With High Slew Rate Option (+HS):
4 ms for an output voltage change from 0 to 63%,
8 ms for an output current change from 0 to 63%.
Bandwidth Standard Models:
3 Hz with remote analog voltage programming,
2 Hz with remote analog current programming.
With High Slew Rate Option (+HS):
60 Hz with remote analog voltage programming,
45 Hz with remote analog current programming.
Physical Specifications
Power Size (H" x D" x W") Rack Units Weight
5 kW 5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm) 3U 74 lbs (34.57 kg)
10 kW 5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm) 3U 94 lbs (42.64 kg))
15 kW 5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm) 3U 125 lbs (56.70 kg)
20 kW 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm) 6U 195 lbs (88.45 kg)
25 kW 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm) 6U 220 lbs (99.79 kg)
30 kW 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm) 6U 245 lbs (111.13 kg)
45 kW 15¾" x 24" x 19" (40.01 x 60.96 x 48.26 cm) 9U 365 lbs (165.56 kg)
Control Specifications
Voltage Programming Accuracy ± 0.075% of full scale voltage
OVT Programming Accuracy ± 0.075% of full scale voltage
Current Programming Accuracy ± 0.075% of full scale current
OCT Programming Accuracy ± 0.075% of full scale current
Voltage Readback Accuracy ± 0.2% of full scale voltage
Current Readback Accuracy ± 0.2% of full scale current
External Analog Programming and Monitoring Levels 0 - 10 Vdc
External Analog Output Impedances Voltage output monitoring: 100 Ω
Current output monitoring: 100 Ω
+10 Vdc reference: 1 Ω
External Digital Programming and Monitoring Limits Input: 0 to 5 Vdc, 10 kΩ input impedance
Output: 0 to 5 Vdc, 5 mA drive capacity
Remote Sense Limits 3% maximum voltage drop from output to load
Environmental
Operating Temperature 0°C to 50°C
Storage Temperature -25°C to +85°C
Ambient Temperature 0 to 50°C
Temperature Coefficient 0.04%/°C of maximum output voltage,
0.06%/°C of maximum output current.
Air Cooling (Standard) Side air inlet, rear exhaust
Water Cooling (Optional) 25°C maximum inlet temperature
1.5 GPM minimum flow rate for 15 kW units
3.0 GPM minimum flow rate for 20-30 kW units
4.5 GPM minimum flow rate for 45 kW units
80 PSI maximum pressure
1/4” NPT female pipe size