GL7000
GL7000
GL7000 specifications
Item | Description | |
---|---|---|
Model number | GL7000 | |
Number of module | Attached to up to 10 modules (*1) | |
Number of input channels | Max. 112 channels in 1 of GL7000 | |
External Input/Output signals (*2) | Input |
Start/Stop, External trigger, External sampling, Auto balance (*3) Signal type: Contact (relay), Open collector, Voltage |
Output |
Trigger, Busy (*3), Alarm (10 channels) (*4) Signal type: Open collector (pulled-up by resistor 10 kΩ) |
|
Trigger, Alarm function | Trigger action | Start or stop capturing data by the trigger |
Trigger repeat |
Enabled (ON): Automatically re-armed for the next data capture function Disabled (OFF): Data capture is completed in a single trigger |
|
Trigger source |
Start: Off, Measured signal, Alarm, External signal, Clock, Week or Time Stop: Off, Measured signal, Alarm, External signal, Clock, Week or Time |
|
Trigger determination conditions for measured signal |
Combination: OR or AND condition at the level of signal or edge of signal Analog: Higher/Rising, Lower/Falling, Window-in, Window-out Logic (*5): Higher/Rising, Lower/Falling Pulse (*5): Higher/Rising, Lower/Falling, Window-in, Window-out |
|
Alarm determination condition (*6) |
Combination: OR or AND condition at the level of signal or edge of signal Analog: Higher/Rising, Lower/Falling, Window-in, Window-out Logic (*5): Higher/Rising, Lower/Falling Pulse (*5): Higher/Rising, Lower/Falling, Window-in, Window-out |
|
Alarm output | 10 channels | |
Pre-trigger (*7) | Number of data before trigger: Up to specified number of captured data | |
Calculation function | Between channels | Addition, Subtraction, Multiplication and Division for two analog inputs (Sampling speed is limited up to 10 Samples/s (100 ms interval). Available arithmetic element and the output destination is the analog input channel 1 to 100.) |
Statistical | Select two calculations from Average, Peak, Max., Min. in real time and replay (*8) | |
Move function of the display range | Beginning, center or end of the data, Trigger point, Specific time (absolute, relative), Call cursor | |
Search function | Search for analog signal levels, logic signal pattern, pulse signal levels or alarm point in captured data | |
Annotation function | Comment can be set in each channel (up to 31 alphanumeric characters) | |
Message / Marker Functions |
Message: The registered messages or entered message is able to be recorded for any timing. Up to 8 messages can be pre-registered. Marker: Marker is able to record for occurring alarm or power failure. |
|
Resume | Resume automatically in the same condition after power is recovered as when the power failure occurred during data capture (*9) | |
FFT analysis function (Firmware ver. 1.20 or later) |
Analyzing frequency range | 0.08, 0.2, 0.4, 0.8, 1.6, 2, 3.2, 4, 8, 20, 40, 80, 200, 400, 800 Hz, 2, 4, 8, 20, 40, 80, 200, 400 kHz |
Number of points | 500, 1000, 2000, 4000, 10000 | |
Window function | Rectangular, Hanning, Hamming, Blackman, Flat-top, Exponential | |
Averaging | Summation average, Exponential average, Peak hold | |
Channels | 4 channels | |
Functions | Y-T, Linear, Power, PSD, Cross, Transfer function, Coherence, COP | |
Display mode | Single display, Dual display, Nyquist | |
Interface to PC | Ethernet (10 BASE-T/100 BASE-TX), USB 2.0 (High speed) | |
Network function | WEB server, FTP server, FTP client, NTP client, DHCP client | |
USB drive mode | Emulate the USB memory device (*10) | |
Storage device | Built-in |
RAM (2 million samples, built-in amplifier module), Flash memory (2 GB, built-in the main module) |
External (*11) |
SD card (Support SDHC, up to 32GB) slot, SSD (Approx. 64GB) The file for capturing data is limited up to 2GB. |
|
Data saving function | Captured data (*11) | Built-in RAM, Built-in Flash, SD memory card, SSD (Data is saved directly to it.) |
Data in built-in RAM | Specified number of data up 2 million samples in increments of 1 | |
Auto save (*11) |
Available for the built-in RAM Enabled (ON): Data in the RAM is saved automatically to the built-in Flash, SD memory card, SSD Disabled (OFF): Data in the RAM is not maintained after power is turned off |
|
Capturing mode (*11) |
Mode: Off, Normal, Ring, Relay Ring (*12): Saved most recent data (Number of capturing data: 1000 to 2000000 points, Destination of data: Built-in RAM, Built-in Flash, SD memory card, SSD) Relay (*13): Saved data to multiple file without losing data until capturing data is stopped (Destination of data: Built-in Flash, SD memory card, SSD) |
|
During data capture (*15) | Displaying information in two windows, Hot-swapping the SD memory card, Saving data in between cursors. | |
Backup (*11) |
Backup interval: Off, 1, 2, 6, 12, 24 hrs. Data destination: SD memory card, SSD, FTP server Data destination for backup cannot be specified to the same storage for destination of capturing data. |
|
Engineering Scale function |
Measured value can be converted to the engineering unit Analog voltage: Converts by four reference points (gain, offset) Temperature: Converts by two reference points (offset) Pulse count: Converts by two reference points (gain) |
|
Synchronization between units | Start and Trigger (*14) | |
Accuracy of clock (at 23°C) | ±0.002% (Monthly deviation approx. 50 sec.) | |
Operating environment | 0 to 45°C, 5 to 85% RH (non condensed) | |
Power source | 100 to 240 V AC, 50 to 60Hz | |
Power consumption | 85VA | |
Standard accessories | Quick guide, CD-ROM, AC power cable | |
External dimensions (W x D x H) |
Main module: Approx. 193 x 141 x 160 mm (Excluding Projection), Alarm output terminal: Approx. 30 x 136 x 145 mm (Excluding projection) |
|
Weight | Main module: Approx. 2.2 kg, Alarm output terminal: Approx. 350 g |