HS-20

HS-20

Share:


HS-20

Available in 2 in. and 16 in. through 35 in. sizes, the low-cost HS-series pumps provide high speed, low ultimate pressure, high throughput, high tolerable forepressure, and low backstreaming. The HS-Series diffusion pumps come with full thermal protection and optional quick-cool coils. The 16 in. through 35 in. pumps come with sight glass/fill and drain assemblies, and are available with ASA or ISO flanges.
  • Five-stage fractionating jet purifies pumping fluid and assures low base pressure.
  • High tolerable forepressure.
  • Full thermal protection.
  • Fluid-level sight glass provides quick indication of pump fluid status at all times.
  • Fill and drain assembly for pump oil.
  • Standard gauge port (NW-25) below inlet flange included.
  • Foreline baffle prevents loss of fluid into backing pump system.
  • Optional halo baffle reduces backstreaming without adding height.
Technical Specifications
Pumping Speed, Operating Range
Pumping Speed, AVS 4.1 (1963)
10,000 l/s air, 12,500 l/s He and H2
17,500 l/s Air
Maximum Throughput 12.5 T-l/s (16.7 mbar l/s) in operating range, 18 T-l/s (23 mbar-l/s) @ 0.01 torr
Operating Range 1.3 x 10-3 to 5 x 10-8 torr (1.7 x 10-3 to 6.5 x 10-8 mbar)
Maximum Forepressure No Load: 0.65 torr (0.85 mbar)
Full Load: 0.55 torr (0.72 mbar)
Recommended Backing Pump ɛ100 cfm (170 m3/hr)
Backstreaming Rate, Standard Cold Cap <1.5 x 10-3 mg/cm2/min
Warmup Time 45 minutes
Cooldown Time 85 minutes
Fluid Charge 5 quarts (4.7 liters)
Electrical Requirements 3 ph, 50/60 Hz, 240/415/480 VAC
Pump Power 12,000 watts
Cooling Water Requirements 1.5 gpm (300 l/hr) at 60-80°F (15-26°C)
Water Connections 1⁄4 in. FPT Tee
Recommended Fluid DC-704
 
Speed Curve Graph

HS-20 Diffusion Pump Speed Curve Graph

Pumping Speed/Cold Cap Pumping speed/Halo Baffle Throughput


Outline Drawing

 
 
 
Description Weight kg (lbs) Part Number
HS-20 Pump with standard cold cap
240 V, ASA flanges 264.0 (580.0) 84341308
240 V, ISO flanges 264.0 (580.0) L5922308
415 V, ASA flanges 264.0 (580.0) 84341326
415 V, 8,100 W, ISO flanges 264.0 (580.0) L5922326
480 V, ASA flanges 264.0 (580.0) 84341309
480 V, ISO flanges 264.0 (580.0) L5922309
HS-20 Pump with halo baffle
240 V, ASA flanges 264.0 (580.0) 84341318
240 V, ISO flanges 264.0 (580.0) L5922318
415 V, ASA flanges 264.0 (580.0) 84341336
415 V, ISO flanges 264.0 (580.0) L5922336
480 V, ASA flanges 264.0 (580.0) 84341319
480 V, ISO flanges 264.0 (580.0) L5922319
Accessories
Water-cooled halo baffle 11.0 (25.0) K01855320
Water-cooled baffle with ASA flanges 100.0 (215.0) R1154301
Water-cooled baffle with ISO flanges 70.0 (160.0) R1155301
Centering ring for ISO foreline flange, 160K 0.5 (1.0) IC160SV
Instruction manual   699901140
Replacement Parts (six heaters required per pump)
Heater, 240/415 V 2000 W with leads 0.5 (1.0) 647320020
Heater, 480 V 2000 W with leads 0.5 (1.0) 647320030
Heater, 240/415 V 2000 W no leads, pre-May 1990 pumps 0.5 (1.0) 647320060
Heater, 480 V 2000 W no leads, pre-May 1990 pumps 0.5 (1.0) 647320070
Heater crush plate (replace one with each new heater) 0.5 (1.0) K7108001
Heater insulator(one required per pump) 0.5 (1.0) L6514001
Heater clamping plate (six required per pump) 4.0 (8.0) K7107001
O-ring kit for ASA pump, 1 for inlet (butyl, 84349002), 1 for foreline (buna, 2-432), 8 for fill and drain (Viton, 2-213) 0.5 (1.0) K0377165
Upper thermal switch (set at 185 °F/85 °C) 0.5 (1.0) K9050001
Lower thermal switch (set at 390 °F/199 °C) 0.5 (1.0) K9050002
Heater Retrofit Kits (for pumps built before May, 1990)
HS-20 pump, 240 V 13.6 (30.0) L6392308
HS-20 pump, 415 V 13.6 (30.0) L6392326
HS-20 pump, 480 V 13.6 (30.0) L6392309